Elpro 605M-R1 GSM/ GPRS Router
Stock Code:
SKU: Elpro605M-R1
The 605M-R1 Industrial Router provides data routing functionality between multiple connected TCP/IP devices. Since TCP/IP connections are point-to-point only, a number of remote TCP/IP clients may each connect to the 605M-R1 simultaneously, which can then route data between those client devices as necessary. More specifically, when connected to a LAN with internet access, the 605M-R1 can be used to route data between remote 605M-D1 GPRS/GSM modems and/or other Ethernet devices.
The Elpro 605M-R1 unit provides two serial connections (RS-232 and RS-485) as well as a standard RJ45 10/100Mbps Ethernet connection. It is possible to use all three data connections concurrently, allowing the 605M-R1 to act as a Device Server. The 605M-R1 also provides several Modbus protocol features including smart routing of Modbus frames, built-in Modbus RTU and TCP master, and Modbus TCP to RTU conversion.
The Elpro 605M-R1 Router connects to a host LAN and can be configured as an Ethernet bridge/router/serial server (RS232/485). The 605M-R1 helps to provide transparents GPRS point to multi-point communications and negates the need for costly static IP addressing.
The combination of multiple 605M-D1 mdodems and the 605M-R1 Router helps to reduce/remove costs associated with data acquisition (ie download/upload) and telecommunication network access (eg static IP addressing and costs).
The Elpro 605M-R1 Router connects to a host LAN and can be configured as an Ethernet bridge/router/serial server (RS232/485). The 605M-R1 helps to provide transparents GPRS point to multi-point communications and negates the need for costly static IP addressing.
The combination of multiple 605M-D1 mdodems and the 605M-R1 Router helps to reduce/remove costs associated with data acquisition (ie download/upload) and telecommunication network access (eg static IP addressing and costs).
- Ethernet bridge/router/serial server modes
- Supports broadcast, master/slave and Modbus aware communication modes to reduce telecommunication costs
- Modbus RTU/TCP Master for field device network control
- Detects IP addressing/maintains network links
- Dual redundancy functionality (with second router on LAN)
Indicative Applications
|
|
Elpro 605M-R1 I/O counts
| Digital Inputs |
1 (Voltage free) |
| Digital Outputs |
1 FET (30VDC, 500mA) |
General Specifications
| Temperature | -35°C to +65°C |
| Humidity | 0-99%RH Non-Condensing |
| Housing | Powder-coated extruded aluminium: 115 x 141 x 32m Weight: 500g |
| Mounting | DIN rail mounting |
| Terminal strip | Removable: up to 2.5mm2 (12 gauge AWG wires) |
| Approvals | EMC FCC Part15, AS3548, 89/336/EEC |
Below is a list of tags that have been applied to this product. Clicking on a tag will display a list of all products with that tag applied.