Elpro 115S Serial Expansion (Remote I/O)

Elpro 115S Serial Expansion (Remote I/O)
Stock Code:
SKU: product options
 
Connected via RS485 and communicating either Elpro or Modbus protocols, Elpro's 115S series expansion products are avialable in three versions of I/O count and able to be used in the following modes:
  • Expansion I/O for Elpro 105U wireless I/O units (up to 10 x 115S units can be connected to each wireless unit)
  • I/O capability for Elpro's serial and 802.11 wireless Ethernet units (up to 99 x 115S units per wireless unit)
  • Modbus Slave I/O expansion units (up to 99 x 115S units can be connected to each Modbus Master eg PLC)
  • Serial I/O multiplexer - transfer I/O via RS485 multidrop using WBINet exception reporting control
  • Serial I/O multiplexer - connected 115S units to form a serial multi-drop I/O system using WBINet exception reporting protocol: no Master device required (up to 32 serial addresses per multi-drop link)

Elpro 115S I/O counts

 115S-11
115S-12115S-13
Digital inputs
All digital inputs voltage free contacts
up to 16up to 8up to 8
Digital outputs
All digital outputs FET (30VDC .2A)
up to 16up to 8up to 8
Analog inputs04 "floating"/8 commoned
(0 - 20mA/0 - 10V
0
Analog outputs008 sink/source
(0 - 20mA/0 - 10V)
Pulse inputs4 (first 4 DI only)
(max rate 1KHz
00
Pulse outputs
All pulsed outputs to maximum 100Hz
888

Note: Specifications subject to change.
Selectable digital inputs and outputs are combined channels: when channel used as an output, it is not available as an input.
Pulse and digital I/O are same connection.

General Specifications

Temperature -40°C to +60°C
Humidity
0-99%RH Non-Condensing
Housing High density thermoplastic: 150 x 180 x 35mm
MountingDIN rail mounting
Terminal stripRemovable: up to 2.5mm2 (12 gauge AWG wires)
Approvals
 
EMC FCC Part 15, AS3548, 89/336/EEC

Power Supply Specifications

Battery supply9 - 30VDC
Loop supply
Internal DC/DC converter: 24VDC 250mA (115S-12 only)
Quiscient current draw12V, 150mA: 24V, 90mA

Serial Port

RS232/RS485 serial port115.2Kbps, 7/ 8 bits, n/e/o parity, 1/2 stop bit
RS232
9pin DB9 female connector 9.6Kbps, 8/n/1
(used for programming only)
RS485Terminal connector (serial expansion only, cable up to 2000m)

Note: Specifications subject to change.

Serial I/O for Modbus or WIB-netApplications

Connected via RS485 and communicating either Elpro or Modbus protocols, the 115S series expansion products are available in 3 versions of I/O count and are able to be used in the following modes:

  • Expansion I/O for 105U wireless units
    up to 10 x 115S units can be connected to each wireless unit via RS485 (up to 2 km long).
  • Serial I/O multiplexer
    transfer I/O via RS485 - up to 32 units per multi-drop link.
  • Expansion I/O for Modbus devices
    up to 31 x 115S units can be connected to each Modbus master via RS485 (up to 2 km long)

The Elpro 115S modules are designed to provide I/O expansion for other Elpro products like 105U module. The 115S modules support the Elpro E-Series protocol, and communicate serially via RS232 or RS485. Configuration is done via the
Elpro E-Series configuration utility.
The 115S modules also support Modbus protocol. They may be used as a Modbus slave with any 3rd-party Modbus device, or with the Elpro 105U-G module using Modbus. They support both MODBUS ASCII protocol, and serial unsigned MODBUS RTU, also known as “MODBUS binary”. The Modbus slave address of the 115S is selected via two rotary switches on the bottom panel of the case.
All 115S models provide digital inputs and outputs. Specific models provide analog inputs or analog outputs. Pulsed inputs and pulsed outputs are also available. Several modules may be connected to one master, allowing any combination of I/O types.

  • Variety of application modes above with configurability of I/O products:
  • Minimum configurable 8 (115S-11 has 16) digital I/O channels: each channel can be used as a volt free contact input or FET output (30VDC, 0.2A maximum)
  • The first four digital inputs on the 115S-11 can function as a plulse input (max pulse rate 1KHz). All digital outputs can function as a pulse output (max 100Hz)
  • Pulse inputs provide both totalized count and pulse rate as seperate values
  • Analog inputs selectable as 'floating' dual-terminal differentiual unputs or commoned single-terminal inputs with configurable current (4 - 20Ma) or voltage (0 - 10) options (including scaling, zero and span parameters). All analog inputs have a high/low set point to determine a set-point status and 24VDC, 250mA is provided for loop powering field instruments
  • Analog outputs selectable as single-terminal source or sink outputs with configurable current (4 - 20mA) or voltage (0 - 10) options
  • Diagnostics including display I/O inputs and/or force I/O outputs and monitoring and confirming of communications
  • Class 1 Div 2 hazardous area approval

Indicative Applications

  • Flow meter monitoring
  • Storage tank monitoring
  • Pipeline cathodic protection
  • Pump stop-start
  • Lighting bank control
  • Power reticulation relay fault notifications
  • Emergency shower notification
  • Weather station reporting
  • Bearing condition monitoring
  • Modbus Slave I/O



 

Elpro 115S - Pump stop-startElpro 115S - Storage tank monitoring
Elpro 115S - Pipeline cathodic protectionElpro 115S - Emergency shower notification

Notes: