Elpro 105U-G-MD1 Modbus RTU

Elpro 105U-G-MD1 Modbus RTU
Stock Code:
SKU: 105U-G-MD1
 
The Elpro 105U-G-MD1 can be configured for Modbus master interface, Modbus slave, or DF1. It has two serial connections - RS232 and RS485, on the bottom end plate of the module. The serial port provides both RS232 and RS485 hardware connections, however both connections are paralleled internally - both connections cannot be used at the same time. Either RS232 or RS485 can be used for Modbus communications, however only the RS232 port can be used for DF1. The serial port must be configured to suit the host device. Serial data rates between 1200 and 19200 baud may be selected, and character types with 7 or 8 data bits, even/odd/none parity, and 1 or 2 stop bits may be selected. The Modbus/DF1 105G has 4300 general-purpose I/O registers. Each discrete, analog and pulse I/O point takes up one register.
  • AC/DC/battery power options, UPS battery charger and solar regulator
  • Interconnects similar/dissimilar industrial protocols (Master/Slave, Slave/Slave, Master/Master) connecting to databus at full speed (e.g. 12 Mbps Profibus)
  • Eight on-board digital I/O which can be configured as either inputs or outputs. Additional internal I/O points include low/normal supply/battery voltage (analog)
  • Point to multi-point connectivity with forward error correction, communications integrity check with security encryption
  • Online read/write of register I/O, reporting of signal strength (RSSI) with diagnostics including radio path measurement and communications logging

Indicative Applications

  • PLC - PLC
    -Similar/dissimilar databuses
  • Storage tank monitoring
  • SCADA System and remote PLC connection
  • One way and Multi I/O interconnection to PLCs and DCS/HMI
  • Moving machinery PLC to PLC/HMI connection
  • Databus cable replacement
  • Smart instrument interface and connection





 
Elpro 105U-G-MD1 - Moving crane controlElpro 105U-G-MD1 - Mines
Elpro 105U-G-MD1 - Water controlElpro 105U-G-MD1 - Waste water control

Radio Frequency and TX Power Option Availability

FrequencyFrequency BandTX Power Channel Spacing
400MHz
360 - 512MHz10 - 500mW, 0.5 - 5W12.5/20/25KHz
868MHz868.525MHz500mW250KHz

Note:

Specifications subject to change.
 

I/O Specifications and Ports

Digital I/O onboard
Eight non voltage/FET I/O: 30VDC 500mA
(D I/O configurable as either inputs or outputs)
RS232 Serial Port
9pin DB9 female connector (used for programming only)
9600 baud, 8 bits, no parity, 1 stop bit
RS485 Serial PortTerminal connector (serial expansion only, cable up to 2000m)
9600 baud, 8 bits, no parity, 1 stop bit
Ethernet Port
RJ45 connector

10/100 Mbps transformer isolated interface

Note:

Specifications subject to change.
 

General Specifications

Temperature -40°C to +60°C
Humidity
0-99%RH Non-Condensing
Housing Extruded aluminium: 130 x 185 x 60mm
MountingDIN mounting
Terminal stripRemovable: up to 2.5mm2 (12 gauge AWG wires)
Approvals
Safety
EMC FCC Part 15, AS3548, EN 301 489
EN60950 RoHS compliant

Power Supply Specifications

Mains supply12 - 24VAC/9 - 30VDC: over-voltage/reverse power protected
Battery supply11.5 - 15.0VDC (battery supply volts internal I/O value)
Battery charging circuit1.2 - 12AHr batter maximum charge current 0.7 at >12V
Solar regulator
Direct connection solar panel (up to 30W)/solar battery 100AHr
Loop supplyInternal DC/DC converter: 24VDC 150mA
Quiscient current draw12V, 150mA: 24V, 90mA: add 5mA per I/O point used
Transmission current draw+12V, 350mA: 24V, 200mA

Note:

Specifications subject to change.
 

Radio Transceiver

Transmit power
400MHz
868MHz

10 - 500mW, 0.5 - 5W: approved to EN 300 113, EN 300 220
868.525MHz: 500mW
Receiver sensitivity
400MHz
868MHz

-112dBm
-108dBm: 868.525MHz
Line of sight range max*
400MHz
868MHz

100mW EIRP: to 5km
500mW: to 5km
Antenna connector
400MHz
868MHz

BNC female coaxial (with gas discharge arrestor)
SMA female (Surge diverter
: CSD-SMA-2500 with CCTAIL-SMA-M

Note:

Specifications subject to change.
*As with all distances quoted, these are dependant on local terrain/obstacles

Wireless gateways provide connectivity between similar/dissimilar industrial databuses and/or field device I/O (e.g. Ethernet/IP to Profibus, etc.) Connected via RS232/485 and Ethernet, register allocated data-bus values are transmitted/received by radio to and from devices such as PLC's, HMI's, etc.
Flexible by design, Elpro's 105U-G series can multi-hop repeat five times, support a variety of industrial protocols and when combined with Elpro's 1115S and/or I/O products, can create simple to complex I/O products, can create simple to complex I/O networks supporting differing protocols.

Elpro 105U-G-MD1

  • Modbus RTU (Master & Slave), DF1
  • Up to 4300 I/O points: analog and/or discrete
  • Modbus - RS232/485: 300-19200bps
  • DF1 (full duplex) - RS232: 300-19200bps
Below is a list of tags that have been applied to this product. Clicking on a tag will display a list of all products with that tag applied.